Please be aware that the sender information is correct. Do not remove the O-ring which should follow the cartridge. The cartridge should be kept in a frost-proof place and as chill as possible. A long time storage of an unused cartridge is unfavourable for the capacity of the cartridge (water quality and amount). Avoid the drying up of the cartridge by letting the water run off for only a very short period, i.e. while the cartridge is changed.

 

Close the stop valves at the inlet and outlet sides. Remove the pressure from the plant by loosening the airscrew or the bottom drain valve. 

 

Screw off the plant top flange, remove the exhausted cartridge, and hang it to drip briefly. Drain the water out of the plant by opening the bottom drain valve.

 

Place the exhausted and dripped-dry, however, not dried up cartridge in the plastic bag which is carefully tied up and placed in the original packing which is returned to EUROWATER.

 

Open the bag with the new cartridge and use it as a funnel for the cartridge that is slowly lowered into the plant. Hold the plastic bag and squeeze the cartridge together in order to slide it easily into the plant. When the cartridge is entirely in the plant, pull out the plastic bag. To smooth down possible creases in the bag, pull the clamp slightly upwards. As it is very important that the cartridge fits tightly inside the plant, vibrate the tank by patting slightly on its outside thus making the cartridge settle.

 

Mount the top flange. N.B! Gasket, O-ring, and bearing surfaces must be clean. Close the bottom drain valve. Open the airscrew. Open the stop valve on the inlet. Close the airwcrew when water flows from the outlet. Open the stop valve on the outlet.

 

Place the exhausted and dripped-dry, however, not dried up cartridge in the plastic bag which is carefully tied up and placed in the original packing. Send it all to